Gas geyser installation in Brackenfell starts with two measurements, not a catalogue: the flow at your furthest shower and the space outside for cylinders. The heater is chosen from those, the gas side is leak-tested, and the certificate of conformity comes with the job.
Say how many bathrooms the heater must serve and where cylinders could stand. The quote comes back in writing.
Six parts of the same job. Each one is a line on the quote, so nothing arrives as an extra on the day.
A continuous-flow unit picked by litres per minute for the taps it must feed at once, not by the size of the old cylinder.
An outdoor-rated unit on an outside wall, or an indoor unit with its flue taken to open air. The house decides which.
Cylinders on a firm base at the distances the standard sets, with a regulator matched to the heater.
Fixed pipework from regulator to heater, clipped, with an isolating valve you can reach.
Cold feed in, hot out to the existing pipes, and the old electric geyser drained and removed if it is going.
The gas side signed off on its own certificate once it has been leak-tested.
How gas certificates work →A continuous-flow gas heater stores nothing. Open a hot tap and water runs through it, a sensor registers the movement, and the burner lights. Close the tap and it goes out. Below a certain flow, a figure printed on the unit’s data plate, the burner does not light at all, and the shower runs cold however full the cylinders are.
That makes the supply to the house part of the appliance. The City of Cape Town’s own figures put normal operating pressure anywhere from 2.4 to 9 bar, and section 24(1) of its Water By-law is plain that the supply is no undertaking to maintain a specific pressure or rate of flow. During drought pressure management, the stated aim was at least 1 bar at the highest point of each zone.
Brackenfell’s zones are still being adjusted. For 10 February 2026 the City warned Brackenfell, Brackenfell South, Protea Hoogte and Protea Village to expect low pressure or no water for six hours while it carried out zone management investigations, and said it could not predict which streets would feel it.
None of this rules gas out. It means the heater is chosen from a measurement taken at your house: litres per minute at the furthest shower, read with a second tap running, and set against the minimum on the data plate. A heater whose minimum sits above the flow the house really gets will keep cutting out, however well it was fitted.
The by-law offers one more number. Under section 52(2), an owner can apply to the City, for a charge, to be told the supply pressure at the property. For most houses the measurement on site is enough, but the option is there.
When you compare gas geyser quotes, look for the measured flow and the heater’s minimum side by side. A quote without both was priced from a catalogue.
Position is set by SANS 10087-1, the LP gas installation standard, and not by where the old geyser happened to be. A heater fitted inside a bathroom has to be flued to the outside and needs ventilation that cannot be shut. An outdoor-rated unit on an external wall needs no flue through the house, which is why it is the simpler choice where a suitable wall exists.
The cylinders carry their own distances. They stand at least 1 m from any door, window or airbrick below the level of the cylinder valve, and 2 m from a drain, pit or manhole, because LP gas is heavier than air and runs along the ground to the lowest opening it finds. From the property boundary the figure is 3 m unless there is a firewall, reduced to 1 m where there are only two cylinders.
The standard also wants a water heater close to the bath or sink it serves. Every extra metre of hot pipe is cold water run to waste before the warm arrives, so the best position is usually the outside wall nearest the main bathroom. On a narrow side passage these numbers pick the spot between them, which is why the tape measure comes out before the price does.
The measured litres per minute, next to the heater’s minimum.
Heater, flue and cylinders marked out and shown to you first.
Every gas joint tested at working pressure before first use.
The gas certificate of conformity handed over at completion.
The quote is built from the heater, the regulator and cylinders, the length of gas line, the water connections and the certificate. An outdoor unit on the wall behind a bathroom is the smallest version of the job. A flued indoor unit or a long pipe run costs more. It is priced in writing after the measurements, and the labour rates are on the plumber prices page.
Only above its minimum flow. Each model states the flow it needs before the burner lights, so the flow at your shower is measured first and the heater matched to it. If the supply itself is weak, our water pressure repairs page covers finding out why.
A unit with battery ignition does, because nothing in it needs mains power. Units with a powered fan or a mains-fed control board do not, so say when you ask for a quote if power cuts are the reason you are switching.
Under SANS 10087-1 a water heater in a bathroom must be flued to the outside and the room needs permanent ventilation. Where an outside wall is close by, an outdoor unit avoids the flue altogether.
Gas geysers are sized in litres per minute, not litres stored. One shower at a time needs a smaller unit than two showers and a kitchen tap together. We ask how the household uses hot water and size to the busiest moment that the measured flow can support.
Yes. A gas installation needs a certificate of conformity from a registered gas installer after it is installed or altered. It is a separate document from the plumbing certificate, as the gas installations page explains.
It can be removed, or left in place and isolated if you would rather keep it as a standby. If it comes out, the old cold feed and hot outlet are reconnected to the gas heater and the roof space is left dry. Other replacement options are on the geyser installation page.
That depends on how much hot water the house uses, so no honest figure fits every home. A two-cylinder changeover means the second takes over when the first runs out, and you refill the empty one at your own pace.